PC-MTS-01
This single system covers all aspects of motor torque measurement, such as speed-torque, cogging torque, and torque ripple. Combined with a power meter, it can be used to measure induced voltage. May be used in combination with environmental testing equipment.
Load torque control range | 0.06 N·m – 2 N·m |
---|---|
Load torque detection accuracy | ±0.5% of range (full scale) |
Allowable RPM | up to 20,000 r/min |
RPM measurement accuracy | ±0.2% of range (full scale) |
Maximum allowable power input | 600 W for five minutes |
Torque detection range | When measuring torque ripple: -2 N·m – 2 N·m When measuring cogging torque: -50 mN·m – 50 mN·m |
---|---|
Torque detection accuracy | When measuring torque ripple: ±0.5% of range (full scale) When measuring cogging torque: ±1.5% of range (full scale) |
Operating RPM | 1 – 20 r/min |
Operating direction of rotation | CW/CCW |
Operating angular measurement resolution | approximately 0.088°(2 r/min or less) approximately 0.35°(3 r/min or more) |
Work operating RPM | 500 – 2,000 r/min |
---|---|
Work torque | 200 mN·m or less |
Voltage measurement | particulars subject to separate consultation |
Compatible personal computers | OS: Microsoft Window XP/7 |