LS-V series LED Strobe/CB-LSV Controller
The LS-V series is a complete set of multifunction LED stroboscopes. It supports diverse stroboscope applications such as surface inspection of steel sheets, paper, and film, checking of printed materials, observation of high-speed rotation and high-speed movement, and measurement of rotation speed. It is equipped with diverse flash functions such as internal trigger flashing, external trigger flashing, delay, frequency division, and slow motion.
Flashing surface comes in six sizes: all 90 mm high with widths of 250 mm, 500 mm, 1,000 mm, 1,250 mm, 1,500 mm, and 2,000 mm. Emits bright and even light using high-brightness white LEDs.
The use of LEDs reduces the labor and running costs of replacing lamps (*). Natural (fan-less) cooling makes maintenance such as replacing filters unnecessary.
(*) Reduces cost by about 300,000 yen per LS-V unit per year (compared with Sugawara SS-800DL).
Controller is easy to operate using a knob and a single screen. Up to 10 settings can be saved using a memory function. It is equipped with diverse flash functions such as internal trigger flashing, external trigger flashing, delay, frequency division, and slow motion.
It can be used as an integrated stroboscope or separately from the controller to support a variety of usage environments. Multiple LS-V units can be connected enabling simultaneous illumination of separated locations or extension of the range of illumination.
In the inspection of printed matter, the number of flashes can be easily set using the conveyor encoder signal and the number of printed sheets. For example, for an encoder with 60 P/R and 7 printed sheets per rotation, there is no need to calculate the division ratio (60÷7=8.5714…)—you only have to set the number of pulses “60” and number of printed sheets “7”.
Two types of Mounting brackets to choose from: L-type and I-type. Using the L-type enables the LS-V to be used as a tabletop stroboscope.
You can choose the model that best fits your usage environment such as illumination range and illumination distance.
Model | Flashing surface width [mm] | Illumination range [mm × mm] | Brightness [LUX] | ||
---|---|---|---|---|---|
Distance 0.3 m | Distance 1 m | Distance 0.3 m | Distance 1 m | ||
LS-V250 | 250 | 250 × 150 | 500 × 500 | 10,000 | 1,600 |
LS-V500 | 500 | 500 × 160 | 600 × 510 | 9,000 | 2,600 |
LS-V1000 | 1,000 | 1,000 × 170 | 1,150 × 520 | 9,000 | 2,600 |
LS-V1250 | 1,250 | 1,250 × 170 | 1,400 × 520 | 9,000 | 2,600 |
LS-V1500 | 1,500 | 1,500 × 170 | 1,650 × 520 | 9,000 | 2,600 |
LS-V2000 | 2,000 | 2,000 × 170 | 2,000 × 520 | 9,000 | 2,600 |
Model | LED Strobe: LS-V250, LS-V500, LS-V1000, LS-V1250, LS-V1500, LS-V2000 Controller: CB-LSV |
---|---|
Flash frequency range | Internal trigger: 30 - 360,000 FPM (0.5–6,000 Hz), Resolution: 1 FPM (0.1 Hz) External trigger: 0–60,000 FPM (0–1,000 Hz), Resolution: 0.1 FPM (0.1 Hz) |
Internal trigger accuracy | ±0.01% |
External trigger measurement accuracy | ±(0.01%+1 digit) |
Flash duration | From 1 μsec to the time equal to 1% of a flash cycle, max. 200 μsec, resolution 0.1 μsec |
Synchronization edge | Voltage signal: Rising edge or falling edgeCurrent signal: Current ON or Current OFFContact signal: Close or Open |
External trigger input signal | Voltage signal: H Level: 3–5 VDC, L Level: 0–1 VDC, Pulse width: 10 μsec or more, Input impedance: Approx. 11 kΩCurrent signal: ON Level: 9–18 mA, OFF Level: 0.1 mA or less, Pulse width: 10 μsec or moreContact signal: ON resistance: 1 kΩ or less, ON current: 18 mA, OFF resistance: 10 kΩ or higher, OFF voltage: 5 V |
Angle Delay | 0 - 359°, Resolution: 1° |
Time Delay | From 0 to input signal cycle or less, max. 2,000 msec, resolution: 1 msec |
External signal frequency division | Maximum division ratio: 1,000 |
Encoder-signal frequency dividing function | Maximum number of encoder signal: 1,000 P/R, maximum number of flashes: 1,000 times/R |
Slow motion | -1.0 r/s (moving forward)–+1.0 r/s (moving backward), Resolution 0.1 r/s |
Memory function | Number of settings that can be saved: 10 |
Number of linked units | max. 12 units |
Power requirement | 100–240 VAC±10%, 50/60Hz |
Usage environment | Temperatures: 0℃–+40℃Humidity: 20%–90%RH, without dew condensation |
Dimensions | LS-V250: 272 mm (W) × 100 mm (H) × 100 mm (D)LS-V500: 522 mm (W) × 100 mm (H) × 100 mm (D)LS-V1000: 1,022 mm (W) × 100 mm (H) × 100 mm (D) LS-V1250: 1,272 mm (W) × 100 mm (H) × 100 mm (D)LS-V1500: 1,522 mm (W) × 100 mm (H) × 100 mm (D)LS-V2000: 2,022 mm (W) × 100 mm (H) × 100 mm (D)CB-LSV: 100 mm (W) × 100 mm (H) × 30 mm (D) |
Weight | LS-V250: 2 kgLS-V500: 3 kgLS-V1000: 5 kgLS-V1250: 6 kgLS-V1500: 7 kgLS-V2000: 9 kgCB-LSV: 400 g |