ADC-101

The Anderon Calibrator ADC-101 is a device for calibrating the Analyzers of the bearing inspection systems. It calibrates the Analyzers by outputting to them the signals corresponding to Anderon/Waviness vibrations. The ADC-101 is equipped with all the functions of our previous Calibrators, enabling calibration of any Analyzers of Sugawara bearing inspection systems.
It also has a function for outputting bearing measurement data saved in USB memory by the Analyzers ADA-105/SWA-105, to other Analyzers as voltage signals.

Calibration

Connection with Analyzer

The ADC-101 sets Anderon/Waviness measurement conditions and measurement values and outputs voltage signals for calibrating the Analyzer. The Analyzer is judged to be operating normally if the values set by the ADC-101 are displayed correctly.

All the Analyzers in our bearing inspection systems can be calibrated in either of two modes

The ADC-101 has two modes. Select the mode according to the Calibrator and the Analyzer you are using.

  • ADC/SWC mode
    This mode functions as the replacement of the previous model Calibrators ADC-10 and SWC-10.
    Measurement Units
    Anderon, nm/sec, um/sec, uinch/sec, cm/s^2, mG, nm, um, uinch, nmWcla, uWcla, nmPC, uPC, nm/rad, um/rad, uinch/rad
  • OSC/ATT mode
    This mode functions as the replacement of the previous models of Signal Generator such as ORC11 and the Attenuator such as EBV-AN01, FOR-102, and DOM-101.
  • ADC/SWC mode
    OSC/ATT mode

    Playback function to reproduce measured vibration signals

    PLAYER mode

    In addition to calibration functions, the ADC-101 has the PLAYER mode to reproduce the measured vibration data saved in the USB memory by the Analyzers ADA-105/SWA-105. The measured vibration data can be easily sent and reproduced without sending sample bearings.

    ※PLAYER mode is available only when the USB memory is connected to the ADC-101.

    Specifications of ADC-101

    Products to be calibrated Bearing vibration testers of input impedance 30 Ω and voltage signal input type
     Anderon Analyzer, Anderon Meter Indication Unit ADA-*
     Synchro Wave Analyzer SWA-*
     Race Wavimeter Indication Unit LWA-*
     Ball Wavimeter Indication Unit BWA-*
    Rotation speed setting 100-9,999 r/min
    Sensor sensitivity setting 0-8.008 Vs/m (0-99.99 mV/usp (usp=12.486 mm/s))
    Oscillation frequency 0-20 kHz
    Unit of measurement Anderon, nm/sec, um/sec, uinch/sec, cm/s^2, mG, nm, um, uinch, nmWcla, uWcla, nmPC, uPC, nm/rad, um/rad, uinch/rad
    ATT setting ATT=(0-60) + (0-9) + (0.0-0.9) dB
    Output level=-(41+ATT) dB of 1 Vrms
    Operation interface 7 inch color LCD touch screen
    Output impedance 30Ω
    Output level Max 4.5 mVrms with input impedance 30Ω
    Power supply 100-240 VAC, 50/60 Hz
    Dimension (W × H × D) and weight 215 (W)×124 (H)×250 (D) mm, 5 Kg